STAAD.Pro Help

Cold-formed Zee Shape Tables

The follow details are used for cold-formed zee shapes in standard database tables.

Note: The required first two columns for all standard databases are RecNo and Name.
Table 1. Zee shape mandatory properties
Name Description Unit Column No.
D Depth in 3
B Width of flange in 4
T Thickness in 5
Table 2. Zee shape optional properties
Name Description Unit Column No.
LIP Width of bottom flange (i.e., lip length) length 6
LIPANGLE Lip angle from flange (default is 90°) degrees 7
RRAD Root radius (inner bend radius) length 8

Spreadsheet Data Examples

Table 3. Zee Section - English units
Name D B T LIP LIIPANGLE RRAD
(in) (in) (in) (in) (deg) (in)
10ZS3.25x105 10 3.25 0.105 0.99 50 0.1875
Table 4. Zee Section - Metric units
Name D B T LIP LIPANGLE
(mm) (mm) (mm) (mm) (deg)
Z160X70X20X2.5JB 160 70 2.5 20 90